4.3 Article

Separation and Preconcentration of Nickel(II) from Drinking, Spring, and Lake Water Samples with Amberlite CG-120 Resin and Determination by Flame Atomic Absorption Spectrometry

期刊

ANALYTICAL SCIENCES
卷 34, 期 10, 页码 1143-1147

出版社

JAPAN SOC ANALYTICAL CHEMISTRY
DOI: 10.2116/analsci.18P086

关键词

Amberlite CG-120 resin; water samples; nickel(II); solid phase extraction

向作者/读者索取更多资源

In this study, Amberlite CG-120 adsorbent was used for the separation/preconcentration of Ni(II) ions in commercial drinking, spring and lake water samples before detection by flame atomic absorption spectrometry. Various optimization parameters for Ni(II) determination, such as pH, eluent type and concentration, sample and eluent flow rates, amount of adsorbent, were investigated to obtain better sensitivity, accuracy, precision and quantitative recovery. Furthermore, the interference effects of some ions on the recovery efficiency of Ni(II) were also investigated. The optimum experimental parameters were obtained in the case of pH 1; 5 mL of 4 mol L-1 HCl for eluent and 0.3 g for the adsorbent amount. The limit of detection was found to be 0.58 mu g L-1 and linearity ranged from 5 to 50 g L-1. The accuracy of the method was tested by the certified reference material of TMDA-70.2 Ontario Lake Water at a 95% confidence level.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据