期刊
ANALYTICAL CHEMISTRY
卷 91, 期 1, 页码 1185-1193出版社
AMER CHEMICAL SOC
DOI: 10.1021/acs.analchem.8b05162
关键词
-
资金
- National Key Research and Development Program of China [2017YFA0206500]
- National Natural Science Foundation of China [21874155, 21635004, 21575163]
We propose an in situ and label-free method for detection of biomolecular recognition events by use of a nanochannel-ion channel hybrid device integrated with an electrochemical detector. The aptamer is first immobilized on the outer surface of the nanochannel-ion channel hybrid. Its binding with target thrombin in solution considerably regulates the mass-transfer behavior of the device owing to the varied surface charge density and effective channel size. Via the electrochemical detector, the changed mass-transport property can be monitored in real time, which enables in situ and label-free detection of thrombin-aptamer recognition. The solution pH has a significant influence on detection sensitivity. Under optimal pH conditions, a detection limit as low as 0.22 fM thrombin can be achieved, which is much lower than most reported work. The present nanofluidic device provides a simple, ultrasensitive, and label-free platform for monitoring biomolecular recognition events, which would hold great potential in exploring the functions and reaction mechanisms of biomolecules in living systems.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐