4.7 Article

Novel non-targeted analysis of perfluorinated compounds using fluorine-specific detection regardless of their ionisability (HPLC-ICPMS/MS-ESI-MS)

期刊

ANALYTICA CHIMICA ACTA
卷 1053, 期 -, 页码 22-31

出版社

ELSEVIER
DOI: 10.1016/j.aca.2018.11.037

关键词

Non-target method; ICPMS/MS; Polyatomic ion [BaF](+); Perfluoroalkyl substances

资金

  1. Malaysian Government [RG12824-10]
  2. National Defence University of Malaysia
  3. Swedish Research Council [FORMAS 1397306]

向作者/读者索取更多资源

Although perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) have been phased out, there is a plethora of per-or polyfluoroalkyl substances (PFAS) generated and only a small number of these compounds are currently being monitored in environmental and biological sample using molecular mass spectrometry (MS). Total fluorine determination has revealed that a substantial amount of fluorinated organic compounds has not been identified. Due to the small mass deficiency of fluorine, it is not an easy task to screen successfully all fluorinated compounds including those which are not easy ionisable, hence a novel fluorine-specific detector is needed. Here, inductively-coupled plasma mass spectrometry (ICPMS) was used for the first time for the detection of PFAS, by using the novel approach to transfer F- into a detectable [BaF](+) in the argon plasma. A reverse phase-high performance liquid chromatography (RP-HPLC) method was developed and then online coupled to ICPMS/MS for the fluorine-specific detection and simultaneously to electrospray MS (ESI-MS) to separate perfluorinated carboxylic acids (PFCA) and perfluorooctanesulfonic acid (PFOS). The calibration was linear and was element-specific with detection limits of 0.49mg F L-1 under gradient elution method. As a proof of concept, PFCA standards in methanol were not fully neutralised to force the esterification and those solutions were measured using HPLC-ICPMS/MS-ESI-MS. The methyl esters were not detectable by ESIMS but by ICPMS/MS. This illustrates that the undetectable fluorine-containing compounds were detected and quantified by the element-specific detection of ICPMS/MS. The analysis of spiked river water at sub-ppb level gave an acceptable recovery using a SPE-based preconcentration method. Since ICPMS/MS method is an element-specific detection, all non-fluorinated compounds interfering in ESI-MS were eliminated. Hence, HPLC-ICPMS/MS can be used as a non-targeted method of fluorinated compounds which helps the identification of novel fluorinated compounds in environmental and biological samples and helps with mining the ESI-MS data. (C) 2018 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据