4.5 Article

Optimization of Acquisition and Analysis Methods for Clinical Dynamic Susceptibility Contrast MRI Using a Population-Based Digital Reference Object

期刊

AMERICAN JOURNAL OF NEURORADIOLOGY
卷 39, 期 11, 页码 1981-1988

出版社

AMER SOC NEURORADIOLOGY
DOI: 10.3174/ajnr.A5827

关键词

-

资金

  1. National Institutes of Health/National Cancer Institute [R01 CA213158]
  2. Arizona Biomedical Research Commission [ADHS16-162414]
  3. Barrow Neurological Foundation [R01CA221938, U01CA220378]

向作者/读者索取更多资源

The accuracy of DSC-MR imaging CBV maps in glioblastoma depends on acquisition and analysis protocols. The authors sought to compare the accuracy of routinely used protocols using a digital reference object that consisted of 10,000 simulated voxels recapitulating typical signal heterogeneity encountered in vivo. The influence of acquisition and postprocessing methods on CBV reliability was evaluated across 6912 parameter combinations, including contrast agent dosing schemes, pulse sequence parameters, field strengths, and postprocessing methods. Across all parameter space, the optimal protocol included full-dose contrast agent preload and bolus, intermediate (60 degrees) flip angle, 30-ms TE, and postprocessing with a leakage-correction algorithm. BACKGROUND AND PURPOSE: The accuracy of DSC-MR imaging CBV maps in glioblastoma depends on acquisition and analysis protocols. Multisite protocol heterogeneity has challenged standardization initiatives due to the difficulties of in vivo validation. This study sought to compare the accuracy of routinely used protocols using a digital reference object. MATERIALS AND METHODS: The digital reference object consisted of approximately 10,000 simulated voxels recapitulating typical signal heterogeneity encountered in vivo. The influence of acquisition and postprocessing methods on CBV reliability was evaluated across 6912 parameter combinations, including contrast agent dosing schemes, pulse sequence parameters, field strengths, and postprocessing methods. Accuracy and precision were assessed using the concordance correlation coefficient and coefficient of variation. RESULTS: Across all parameter space, the optimal protocol included full-dose contrast agent preload and bolus, intermediate (60 degrees) flip angle, 30-ms TE, and postprocessing with a leakage-correction algorithm (concordance correlation coefficient = 0.97, coefficient of variation = 6.6%). Protocols with no preload or fractional dose preload and bolus using these acquisition parameters were generally less robust. However, a protocol with no preload, full-dose bolus, and low (30 degrees) flip angle performed very well (concordance correlation coefficient = 0.93, coefficient of variation = 8.7% at 1.5T and concordance correlation coefficient = 0.92, coefficient of variation = 8.2% at 3T). CONCLUSIONS: Schemes with full-dose preload and bolus maximize CBV accuracy and reduce variability, which could enable smaller sample sizes and more reliable detection of CBV changes in clinical trials. When a lower total contrast agent dose is desired, use of a low flip angle, no preload, and full-dose bolus protocol may provide an attractive alternative.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据