期刊
FRONTIERS IN ENERGY
卷 7, 期 2, 页码 133-139出版社
HIGHER EDUCATION PRESS
DOI: 10.1007/s11708-013-0248-8
关键词
combined heat and power (CHP) economic dispatch; meta-heuristic algorithm; firefly algorithm; cogeneration
Cogeneration units, which produce both heat and electric power, are found in many process industries. These industries also consume heat directly in addition to electricity. The cogeneration units operate only within a feasible zone. Each point within the feasible zone consists of a specific value of heat and electric power. These units are used along with other units, which produce either heat or power exclusively. Hence, the economic dispatch problem for these plants to optimize the fuel cost is quite complex and several classical and meta-heuristic algorithms have been proposed earlier. This paper applies the firefly algorithm, which is inspired by the behavior of fireflies which attract each other based on their luminosity. The results obtained have been compared with those obtained by other methods earlier and showed a marked improvement over the earlier methods.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐