4.7 Article

Heat transfer and air movement behaviour in a double-skin facade

期刊

SUSTAINABLE CITIES AND SOCIETY
卷 10, 期 -, 页码 130-139

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.scs.2013.07.002

关键词

Heat transfer; Natural ventilation; Double Skin Facade; Overheating

资金

  1. Ningbo Science and Technology Bureau, China under the Key Laboratory of Integrated Thermal Energy Storage Technologies (ITEST)

向作者/读者索取更多资源

Theoretical and practical evaluation of a naturally ventilated double skin facade has been undertaken. The study has shown that the double skin facade (DSF) system is capable of supplying adequate ventilation to various levels with little or no additional heating during winter thus saving the bulk percentage of the heating load on the building. However there was an element of overheating in the DSF which may have contributed to an additional cooling load on the building. Even though the operational strategy of mixing return air with trapped air in the cavity helped to minimise the overheating effect, there was still some considerable level of temperature increase in the DSF. Effective thermal management control strategies and systems are therefore encouraged in the design and operation of DSFs. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据