High resolution (3 Tesla) MRI-guided conformal brachytherapy for cervical cancer: consequences of different high-risk CTV sizes

期刊

JOURNAL OF CONTEMPORARY BRACHYTHERAPY
卷 5, 期 2, 页码 101-109

出版社

TERMEDIA PUBLISHING HOUSE LTD
DOI: 10.5114/jcb.2013.36180

关键词

brachytherapy; cervical cancer; high-dose-rate brachytherapy; MRI-guided brachytherapy

向作者/读者索取更多资源

Purpose: To evaluate conventional brachytherapy (BT) plans using dose-volume parameters and high resolution (3 Tesla) MRI datasets, and to quantify dosimetric benefits and limitations when MRI-guided, conformal BT (MRIG-CBT) plans are generated. Material and methods: Fifty-five clinical high-dose-rate BT plans from 14 cervical cancer patients were retrospectively studied. All conventional plans were created using MRI with titanium tandem-and-ovoid applicator (T&O) for delivery. For each conventional plan, a MRIG-CBT plan was retrospectively generated using hybrid inverse optimization. Three categories of high risk (HR)-CTV were considered based on volume: non-bulky (< 20 cc), low-bulky (> 20 cc and < 40 cc) and bulky (>= 40 cc). Dose-volume metrics of D-90 of HR-CTV and D-2cc and D-0.1cc of rectum, bladder, and sigmoid colon were analyzed. Results: Tumor coverage (HR-CTV D-90) of the conventional plans was considerably affected by the HR-CTV size. Sixteen percent of the plans covered HR-CTV D-90 with the prescription dose within 5%. At least one OAR had D-2cc values over the GEC-ESTRO recommended limits in 52.7% of the conventional plans. MRIG-CBT plans showed improved target coverage for HR-CTV D-90 of 98 and 97% of the prescribed dose for non-bulky and low-bulky tumors, respectively. No MRIG-CBT plans surpassed the D-2cc limits of any OAR. Only small improvements (D-90 of 80%) were found for large targets (> 40 cc) when using T&O applicator approach. Conclusions: MRIG-CBT plans displayed considerable improvement for tumor coverage and OAR sparing over conventional treatment. When the HR-CTV volume exceeded 40 cc, its improvements were diminished when using a conventional intracavitary applicator.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据