4.3 Article

Compatibility of medications during multi-infusion therapy: A controlled in vitro study on a multilumen infusion device

期刊

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.accpm.2014.06.003

关键词

Drug delivery systems/instrumentation; Infusions; Parenteral; Drug incompatibilities; Material testing

资金

  1. Departments of Biopharmacy, Galenic and Hospital Pharmacy, EA GRITA, Universite Lille Nord de France, Lille, France
  2. Doran International, Toussieu, France

向作者/读者索取更多资源

Objective: Drug incompatibilities can jeopardize the safety and effectiveness of intravenous drug therapies, especially in the field of anaesthesia and intensive care. Patients receive many drugs simultaneously through limited venous accesses. This study was designed to confirm the impact of a multilumen infusion device on the occurrence of known physical drug incompatibilities. Study design: In vitro laboratory work. Methods: Two infusion devices were studied: a standard single-lumen set and a multilumen infusion access device (Edelvaiss Multiline-8, Doran International). Up to six drugs were infused simultaneously: three acidic solutions of midazolam, amiodarone and dobutamine, and three alkaline solutions of furosemide, pantoprazole and amoxicillin/clavulanate. Saline, Ringer' solution and 5% dextrose were used as hydration vehicles with an infusion rate initially set at 100 mL/h and with stepwise decreases of 10 mL/h until precipitation. Two methods were used to highlight physical drug compatibility according to the European Pharmacopoeia: visual inspection of the extension set and an obscured-light sub-visible particle count test of infusions. The lowest infusion rate value for vehicle infusion to satisfy the two tests in all trials is reported for each infusion device. Results: The standard set did not satisfy the test in 82% of the assessed drug combinations. The Edelvaiss Multiline-8 was able to prevent the occurrence of drug incompatibilities in 49% of the drug combinations tested. This device is therefore advantageous, especially when simultaneously infusing two or four incompatible drugs. Conclusions: Infusion device characteristics have an impact on physical drug incompatibilities. Our results confirm that the Edelvaiss Multiline-8 device prevents physical drug incompatibilities under specified conditions. (C) 2015 Societe francaise d'anesthesie et de reanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据