4.7 Article

Behavior of FRP-Confined Concrete-Filled Steel Tube Columns

期刊

POLYMERS
卷 6, 期 5, 页码 1333-1349

出版社

MDPI AG
DOI: 10.3390/polym6051333

关键词

concrete-filled steel tube (CFST) columns; fiber-reinforced polymer (FRP); axial load; confinement; load capacity

资金

  1. Young Scientist Project of the Natural Science Foundation of China [51108355]
  2. Natural Science Foundation of Hubei Province, China [2011CDB269]
  3. Fundamental Research Funds for the Central Universities, China

向作者/读者索取更多资源

This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap can effectively confine the concrete expansion and delay the local buckling of the steel tube. Both the load capacity and the axial deformation capacity of concrete-filled steel tube columns can be substantially enhanced with FRP confinement. A model is proposed to predict the load capacity of the FRP-confined concrete-filled steel tube columns. The predicted results are generally in good agreement with the experimental ones obtained in this study and in the literature.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据