4.4 Article

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS

期刊

出版社

JOURNAL OF VISUALIZED EXPERIMENTS
DOI: 10.3791/52424

关键词

Medicine; Issue 105; Tacrolimus; dried blood spots; high-performance liquid chromatography; tandem mass spectrometry; LC-MS/MS; column switching; online extraction; therapeutic drug monitoring; home monitoring; adherence monitoring

资金

  1. United States Federal Drug Administration (FDA) [HHSF223201310224C]
  2. United States National Institutes of Health/FDA [1U01FD004573-01]

向作者/读者索取更多资源

The calcineurin inhibitor tacrolimus is the cornerstone of most immunosuppressive treatment protocols after solid organ transplantation in the United States. Tacrolimus is a narrow therapeutic index drug and as such requires therapeutic drug monitoring and dose adjustment based on its whole blood trough concentrations. To facilitate home therapeutic drug and adherence monitoring, the collection of dried blood spots is an attractive concept. After a finger stick, the patient collects a blood drop on filter paper at home. After the blood is dried, it is mailed to the analytical laboratory where tacrolimus is quantified using high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) in combination with a simple manual protein precipitation step and online column extraction. For tacrolimus analysis, a 6-mm disc is punched from the saturated center of the blood spot. The blood spot is homogenized using a bullet blender and then proteins are precipitated with methanol/0.2 M ZnSO4 containing the internal standard D-2, C-13-tacrolimus. After vortexing and centrifugation, 100 mu l of supernatant is injected into an online extraction column and washed with 5 ml/min of 0.1 formic acid/acetonitrile (7: 3, v: v) for 1 min. Hereafter, the switching valve is activated and the analytes are back-flushed onto the analytical column (and separated using a 0.1% formic acid/acetonitrile gradient). Tacrolimus is quantified in the positive multi reaction mode (MRM) using a tandem mass spectrometer. The assay is linear from 1 to 50 ng/ml. Inter-assay variability (3.6%-6.1%) and accuracy (91.7%-101.6%) as assessed over 20 days meet acceptance criteria. Average extraction recovery is 95.5%. There are no relevant carry-over, matrix interferences and matrix effects. Tacrolimus is stable in dried blood spots at RT and at +4 degrees C for 1 week. Extracted samples in the autosampler are stable at +4 degrees C for at least 72 hr.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据