4.2 Article

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

期刊

EARTHQUAKES AND STRUCTURES
卷 4, 期 6, 页码 649-670

出版社

TECHNO-PRESS
DOI: 10.12989/eas.2013.4.6.649

关键词

base-isolation; building connection; hybrid system; passive damper; structural control; robustness; redundancy

资金

  1. Japan Society for the Promotion of Science [24246095]

向作者/读者索取更多资源

It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据