4.7 Article

Gold nanospikes based microsensor as a highly accurate mercury emission monitoring system

期刊

SCIENTIFIC REPORTS
卷 4, 期 -, 页码 -

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/srep06741

关键词

-

资金

  1. Australian Research Council (ARC) [LP100200859, DP0988099]
  2. ARC [LP100200859, FT140101285]
  3. Australian Research Council [DP0988099] Funding Source: Australian Research Council

向作者/读者索取更多资源

Anthropogenic elemental mercury (Hg-0) emission is a serious worldwide environmental problem due to the extreme toxicity of the heavy metal to humans, plants and wildlife. Development of an accurate and cheap microsensor based online monitoring system which can be integrated as part of Hg-0 removal and control processes in industry is still a major challenge. Here, we demonstrate that forming Au nanospike structures directly onto the electrodes of a quartz crystal microbalance (QCM) using a novel electrochemical route results in a self-regenerating, highly robust, stable, sensitive and selective Hg-0 vapor sensor. The data from a 127 day continuous test performed in the presence of volatile organic compounds and high humidity levels, showed that the sensor with an electrodeposted sensitive layer had 260% higher response magnitude, 3.4 times lower detection limit (similar to 22 mu g/m(3) or similar to 2.46 ppb(v)) and higher accuracy (98% Vs 35%) over a Au control based QCM (unmodified) when exposed to a Hg-0 vapor concentration of 10.55 mg/m(3) at 101 degrees C. Statistical analysis of the long term data showed that the nano-engineered Hg-0 sorption sites on the developed Au nanospikes sensitive layer play a critical role in the enhanced sensitivity and selectivity of the developed sensor towards Hg-0 vapor.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据