4.6 Article

A handheld stamping process to fabricate microfluidic paper-based analytical devices with chemically modified surface for clinical assays

期刊

RSC ADVANCES
卷 4, 期 71, 页码 37637-37644

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/c4ra07112c

关键词

-

资金

  1. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq) [478911/2012-2]
  2. Fundacao de Amparo a Pesquisa do Estado de Goias (FAPEG)
  3. Instituto Nacional de Ciencia e Tecnologia de Bioanalitica (INCTBio)
  4. CNPq [311323/2011-1, 311744/2013-3]

向作者/读者索取更多资源

This paper describes the development and use of a handheld and lightweight stamp for the production of microfluidic paper-based analytical devices (mPADs). We also chemically modified the paper surface for improved colorimetric measurements. The design of the microfluidic structure has been patterned in a stamp, machined in stainless steel. Prior to stamping, the paper surface was oxidized to promote the conversion of hydroxyl into aldehyde groups, which were then chemically activated for covalent coupling of enzymes. Then, a filter paper sheet was impregnated with paraffin and sandwiched with a native paper (n-paper) sheet, previously oxidized. The metal stamp was preheated at 150 degrees C and then brought in contact with the paraffined paper (p-paper) to enable the thermal transfer of the paraffin to the n-paper, thus forming the hydrophobic barriers under the application of a pressure of ca. 0.1 MPa for 2 s. The channel and barrier widths measured in 50 independent mPADs exhibited values of 2.6 +/- 0.1 and 1.4 +/- 0.1 mm, respectively. The chemical modification for covalent coupling of enzymes on the paper surface also led to improvements in the colour uniformity generated inside the sensing area, a known bottleneck in this technology. The relative standard deviation (RSD) values for glucose and uric acid (UA) assays decreased from 40 to 10% and from 20 to 8%, respectively. Bioassays related to the detection of glucose, UA, bovine serum albumin (BSA), and nitrite were successfully performed in concentration ranges useful for clinical assays. The semi-quantitative analysis of all four analytes in artificial urine samples revealed an error smaller than 4%. The disposability of mu PADs, the low instrumental requirements of the stamp-based fabrication, and the improved colour uniformity enable the use of the proposed devices for the point-of-care diagnostics or in limited resources settlements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据