4.5 Article Proceedings Paper

Image-guided placement of the Bonebridge without surgical navigation equipment

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s11548-013-0973-9

关键词

STAMP; Bonebridge; Image-guided surgery; Template; Surgical navigation

资金

  1. Japan Society for the Promotion of Science (JSPS) KAKENHI [24500549]
  2. Grants-in-Aid for Scientific Research [26108001, 26108010, 24500549] Funding Source: KAKEN

向作者/读者索取更多资源

Most of the current Bonebridge surgeries undergo preoperative simulation planning in a computer. However, surgeons usually use the landmarks on the bone surface to determine the location where to implant the device, using the simulation image in the computer only as a reference (conventional method). We developed an image-guided method for precisely replicating simulation surgery upon performing Bonebridge implantation. Based on our previous development of the surface template-assisted marker positioning (STAMP) method for performing image-guided otologic surgery, we fabricated templates that fit only at the designated location on the patient's temporal bone surface. The Bonebridge STAMP (BB-STAMP) plate shows the exact location where to start drilling. The BB-STAMP was also combined with a perforator-guiding sleeve, so that the location, direction and depth of the cylindrical well could be precisely replicated as simulated. We also created a STAMP plate for confirmation that fits only after sufficient drilling at the correct location is finished. To evaluate the proposed methods, we performed simulation surgery on four cadaveric temporal bones and their 12 replicas (three each for four bones). The time used and the degree of mismatch between the simulated location and the drilled location were compared. A feasibility study was successfully conducted using the proposed BB-STAMP methods and the conventional method. The amount of time required for the procedure did not differ significantly between the surgical methods, although using the BB-STAMP and perforator guide was always quicker. The degree of mismatch between the simulation and resected models had tendency to be smaller when the surgery was guided by the BB-STAMP with or without a perforator guide, although the difference was not statistically significant. The proposed BB-STAMP is a promising method for replicating exactly what is performed during simulation without using a surgical navigation system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据