4.4 Article

Variability of Tear Osmolarity in Patients With Dry Eye

期刊

JAMA OPHTHALMOLOGY
卷 133, 期 6, 页码 662-667

出版社

AMER MEDICAL ASSOC
DOI: 10.1001/jamaophthalmol.2015.0429

关键词

-

资金

  1. National Eye Institute [K12-EY-015398, P30 EY001583]
  2. Research to Prevent Blindness

向作者/读者索取更多资源

IMPORTANCE Knowledge about the variability of measurements using the TearLab Osmolarity System is necessary when evaluating the clinical utility of readings. OBJECTIVE To examine the variability of tear osmolarity measured by the TearLab Osmolarity System in patients with Sjogren syndrome (SS), patients with blepharitis, and control participants. DESIGN, SETTING, AND PARTICIPANTS Cross-sectional study at a tertiary care academic center from June 13, 2012, to March 21, 2013. Participants included 74 eyes of 37 patients from a volunteer sample (18 patients with SS, 11 patients with blepharitis, and 8 control participants) who were evaluated using the TearLab Osmolarity System, with 3 consecutive osmolarity measurements taken at 1-minute intervals in a session; 15 of these patients had the same measurements taken by the same examiner in 2 additional sessions on the same day (9 AM-10 AM, 12 PM-1 PM, or 3 PM-4 PM). Most patients with SS and patients with blepharitis were taking systemic or topical dry eye medications at the time of enrollment. MAIN OUTCOMES AND MEASURES Mean osmolarity and its variability calculated from a linear mixed model for each disease group that accounts for the variations attributable to different patients, eyes, and sessions and measurement error specific to each disease group. RESULTS Mean tear osmolarity was 307mOsm/L, 304mOsm/L, and 301mOsm/L in the SS, blepharitis, and control groups, respectively (P = .46). The error associated with repeated measurements within a session in the patients without dry eye (10.5mOsm/L [95% CI, 9.0-12.4]) was significantly lower than in the patients with blepharitis (14.6mOsm/L [95% CI, 12.5-17.5]; P = .006) and patients with SS (15.8mOsm/L [95% CI, 14.2-17.8]; P < .001) but a difference in the error of repeated measurements between patients with blepharitis and patients with SS was not identified (P = .46). CONCLUSIONS AND RELEVANCE There was increased variability attributable to error in repeated measurements in patients with SS and patients with blepharitis compared with control participants. The high variability of TearLab osmolarity readings in all groups makes the clinical interpretation of measurements unclear.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据