4.4 Article

Resolution of the three dimensional structure of components of the glomerular filtration barrier

期刊

BMC NEPHROLOGY
卷 15, 期 -, 页码 -

出版社

BMC
DOI: 10.1186/1471-2369-15-24

关键词

Urinary space; Podocyte; Glycocalyx; GFB; Tomography; Serial block face (SBF); Focused ion beam (FIB); Electron microscopy; Glomerulus; 3D reconstruction

资金

  1. Science City Research Alliance
  2. British Heart Foundation [PG/08/059/25335]
  3. MRC [G0802829, G10002073]
  4. Richard Bright VEGF research trust
  5. MRC [G0802829, G0600920, G1002073] Funding Source: UKRI
  6. British Heart Foundation [PG/08/059/25335] Funding Source: researchfish
  7. Kidney Research UK [IN9/2013] Funding Source: researchfish
  8. Medical Research Council [G0802829, G0600920, G1002073] Funding Source: researchfish

向作者/读者索取更多资源

Background: The human glomerulus is the primary filtration unit of the kidney, and contains the Glomerular Filtration Barrier (GFB). The GFB had been thought to comprise 3 layers - the endothelium, the basement membrane and the podocyte foot processes. However, recent studies have suggested that at least two additional layers contribute to the function of the GFB, the endothelial glycocalyx on the vascular side, and the sub-podocyte space on the urinary side. To investigate the structure of these additional layers is difficult as it requires three-dimensional reconstruction of delicate sub-microscopic (<1 mu m) cellular and extracellular elements. Methods: Here we have combined three different advanced electron microscopic techniques that cover multiple orders of magnitude of volume sampled, with a novel staining methodology (Lanthanum Dysprosium Glycosaminoglycan adhesion, or LaDy GAGa), to determine the structural basis of these two additional layers. Serial Block Face Scanning Electron Microscopy (SBF-SEM) was used to generate a 3-D image stack with a volume of a 5.3 x 10(5) mu m(3) volume of a whole kidney glomerulus (13% of glomerular volume). Secondly, Focused Ion Beam milling Scanning Electron Microscopy (FIB-SEM) was used to image a filtration region (48 mu m(3) volume). Lastly Transmission Electron Tomography (Tom-TEM) was performed on a 0.3 mu m(3) volume to identify the fine structure of the glycocalyx. Results: Tom-TEM clearly showed 20 nm fibre spacing in the glycocalyx, within a limited field of view. FIB-SEM demonstrated, in a far greater field of view, how the glycocalyx structure related to fenestrations and the filtration slits, though without the resolution of TomTEM. SBF-SEM was able to determine the extent of the sub-podocyte space and glycocalyx coverage, without additional heavy metal staining. Neither SBF- nor FIB-SEM suffered the anisotropic shrinkage under the electron beam that is seen with Tom-TEM. Conclusions: These images demonstrate that the three dimensional structure of the GFB can be imaged, and investigated from the whole glomerulus to the fine structure of the glycocalyx using three dimensional electron microscopy techniques. This should allow the identification of structural features regulating physiology, and their disruption in pathological states, aiding the understanding of kidney disease.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据