4.6 Article

OCT Compared With IVUS in a Coronary Lesion Assessment The OPUS-CLASS Study

期刊

JACC-CARDIOVASCULAR IMAGING
卷 6, 期 10, 页码 1095-1104

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2013.04.014

关键词

coronary angiography; intravascular ultrasound; optical coherence tomography

资金

  1. Lightlab Imaging/St Jude Medical
  2. St. Jude Medical

向作者/读者索取更多资源

OBJECTIVES The aim of this study was to investigate the reliability of frequency domain optical coherence tomography (FD-OCT) for coronary measurements compared with quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). BACKGROUND Accurate luminal measurement is expected in FD-OCT because this technology offers high resolution and excellent contrast between lumen and vessel wall. METHODS In 5 medical centers, 100 patients with coronary artery disease were prospectively studied by using angiography, FD-OCT, and IVUS. In addition, 5 phantom models of known lumen dimensions (lumen diameter 3.08 mm; lumen area 7.45 mm(2)) were examined using FD-OCT and IVUS. Quantitative image analyses of the coronary arteries and phantom models were performed by an independent core laboratory. RESULTS In the clinical study, the mean minimum lumen diameter measured by QCA was significantly smaller than that measured by FD-OCT (1.81 +/- 0.72 mm vs. 1.91 +/- 0.69 mm; p < 0.001) and the minimum lumen diameter measured by IVUS was significantly greater than that measured by FD-OCT (2.09 +/- 0.60 mm vs. 1.91 +/- 0.69 mm; p < 0.001). The minimum lumen area measured by IVUS was significantly greater than that by FD-OCT (3.68 +/- 2.06 mm(2) vs. 3.27 +/- 2.22 mm(2); p < 0.001), although a significant correlation was observed between the 2 imaging techniques (r = 0.95, p < 0.001; mean difference 0.41 mm(2)). Both FD-OCT and IVUS exhibited good interobserver reproducibility, but the root-mean-squared deviation between measurements was approximately twice as high for the IVUS measurements compared with the FD-OCT measurements (0.32 mm(2) vs. 0.16 mm(2)). In a phantom model, the mean lumen area according to FD-OCT was equal to the actual lumen area of the phantom model, with low SD; IVUS overestimated the lumen area and was less reproducible than FD-OCT (8.03 +/- 0.58 mm(2) vs. 7.45 +/- 0.17 mm(2); p < 0.001). CONCLUSIONS The results of this prospective multicenter study demonstrate that FD-OCT provides accurate and reproducible quantitative measurements of coronary dimensions in the clinical setting. (C) 2013 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据