4.6 Article

3D Echocardiography to Evaluate Right Atrial Pressure in Acutely Decompensated Heart Failure Correlation With Invasive Hemodynamics

期刊

JACC-CARDIOVASCULAR IMAGING
卷 4, 期 9, 页码 938-945

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2011.05.006

关键词

cardiac volume; echocardiography; heart failure; imaging

向作者/读者索取更多资源

OBJECTIVES This study examined the utility of 3-dimensional right atrial volume index (3D-RAVi), combined with 2-dimensional echocardiographic (2DE) parameters, for the identification of elevated right atrial pressure (RAP) in patients with heart failure. BACKGROUND Accurate noninvasive determination of RAP is clinically important for the management of patients with heart failure. Although 2DE methods have been used to noninvasively estimate RAP, the accuracy of these parameters has limitations when estimating RAP in an individual patient. Three-dimensional echocardiography (3DE) provides tomographic imaging of right atrial volume that may be helpful in refining the noninvasive assessment of hemodynamics in patients with heart failure. METHODS 2DE and 3DE studies were examined in 40 initial patients who were admitted for acutely decompensated heart failure. Simultaneous pulmonary artery catheter monitoring was performed. The relationship between echocardiographic parameters and RAP was examined in this derivation group. The findings from the derivation group were then prospectively tested in a validation group of 40 additional patients. RESULTS Mean RAP was 11 +/- 5 mm Hg (range 2 to 22 mm Hg). 3D-RAVi correlated with RAP (r = 0.51, p < 0.001), whereas 2-dimensional right atrial volume index did not. Inferior vena cava (IVC) diameter cm and IVC respirophasic collapse < 40% also correlated with RAP (p < 0.001 and p = 0.028, respectively). Based on receiver-operator characteristic curve analysis, 3D-RAVi >= 35 ml/m(2) was the optimal 3D-RAVi cutpoint for identifying RAP > 10 mm Hg. The value of 3D-RAVi ml/m(2), combined with IVC measures, for predicting RAP > 10 mm Hg was prospectively tested in the validation group. 3D-RAVi >= 35 ml/m(2) in combination with IVC >= 2 cm had a high accuracy (88%) for identifying RAP > 10 mm Hg and had a higher accuracy than the combination of IVC >= 2 cm and IVC collapse < 40% (accuracy: 68%, p = 0.038). CONCLUSIONS In patients with heart failure, 3D-RAVi in conjunction with IVC parameters has a high accuracy for detection of elevated RAP. The addition of 3D-RAVi to 2DE methods may be helpful in the noninvasive estimation of right atrial pressure. (J Am Coll Cardiol Img 2011;4:938-45) (C) 2011 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据