4.6 Article

Hemodynamic Stress Echocardiography in Patients Supported With a Continuous-Flow Left Ventricular Assist Device

期刊

JACC-CARDIOVASCULAR IMAGING
卷 3, 期 8, 页码 854-859

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2010.06.007

关键词

echocardiograph; exercise test; heart failure; left ventricular assist device

资金

  1. Fonds de la recherche en sante du Quebec

向作者/读者索取更多资源

Functional assessment of continuous-flow left ventricular assist devices (LVADs) is usually performed with the patient at rest. This study compared echocardiographic indices of contraction and filling pressure with invasive measures in 12 ambulatory LVAD patients undergoing symptom-limited bicycle exercise. Exercise induced an increase in cardiac output, systolic pulmonary artery pressure, and diastolic pulmonary artery pressure. Although no changes in left ventricular dimensions or fractional shortening were seen on echocardiography, systolic mitral annular motion (S') increased significantly (in parallel with cardiac output) and diastolic E/e' ratio decreased (correlating inversely with diastolic pulmonary artery pressure). These findings emphasize the potential role of exercise echocardiography in studying exercise hemodynamics in LVAD patients. (J Am Coll Cardiol Img 2010; 3:854-9) (C) 2010 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据