4.6 Article

Regadenoson Induces Comparable Left Ventricular Perfusion Defects as Adenosine A Quantitative Analysis From the ADVANCE MPI 2 Trial

期刊

JACC-CARDIOVASCULAR IMAGING
卷 2, 期 8, 页码 959-968

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcmg.2009.04.011

关键词

single photon tomography; regadenoson; adenosine

资金

  1. Astellas
  2. CV Therapeutics
  3. CV Therapeutics, Inc.

向作者/读者索取更多资源

OBJECTIVES This study sought to determine whether regadenoson induces left ventricular perfusion defects of similar size and severity as seen with adenosine stress. BACKGROUND Total and ischemic left ventricular perfusion defect size predict patient outcome. Therefore, it is important to show that newer stressor agents induce similar perfusion abnormalities as observed with currently available ones. METHODS The ADVANCE MPI 2 (Adenosine versus Regadenoson Comparative Evaluation for Myocardial Perfusion Imaging) study was a prospective, double-blind, randomized trial comparing image results in patients undergoing standard gated adenosine single-photon emission computed tomography (SPECT) myocardial perfusion imaging who were then randomized in a 2: 1 ratio to either regadenoson (N = 495) or a second adenosine SPECT (N = 260). Quantitative SPECT analysis was used to determine total left ventricular perfusion defect size and the extent of ischemia. Quantification was performed by a single observer who was blinded to randomization and image sequence. RESULTS Baseline gated perfusion results were similar in patients randomized to adenosine or regadenoson. No significant differences in total (11.5 +/- 15.7 vs. 11.4 +/- 15.8, p = 0.88) or ischemic (4.8 +/- 9.2 vs. 4.6 +/- 8.9, p = 0.43) perfusion defect sizes were observed between the regadenoson and adenosine groups, respectively. Linear regression showed a close correlation between adenosine and regadenoson for total (r = 0.97, p < 0.001) and ischemic (r = 0.95, p < 0.001) left ventricular perfusion defects. Serial differences in total (-0.03 +/- 3.89 vs. -0.13 +/- 4.16, p = 0.73) and ischemic (0.15 +/- 4.08 vs. 0.25 +/- 3.81, p = 0.74) perfusion defect size and left ventricular ejection fraction (0.12 +/- 0.32 vs. 0.15 +/- 0.35, p = 0.27) from study 1 to study 2 were virtually identical in patients randomized to regadenoson versus adenosine, respectively. The good correlation between serial adenosine and regadenoson studies regarding total (0.41 +/- 5.43 vs. 0.21 +/- 5.23, p = 0.76) and ischemic (0.17 +/- 5.31 vs. 0.23 +/- 6.08, p = 0.94) perfusion defects persisted in the subgroup of 308 patients with an abnormal baseline SPECT. CONCLUSIONS Applying quantitative analysis, regadenoson induces virtually identical scintigraphic results as adenosine regarding the size and severity of left ventricular perfusion defects and the extent of scintigraphic ischemia. (J Am Coll Cardiol Img 2009;2:959-68) (C) 2009 by the American College of Cardiology Foundation

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据