4.6 Article

Role of diffusion-weighted magnetic resonance imaging in the diagnosis of extrahepatic cholangiocarcinoma

期刊

WORLD JOURNAL OF GASTROENTEROLOGY
卷 16, 期 25, 页码 3196-3201

出版社

BAISHIDENG PUBL GRP CO LTD
DOI: 10.3748/wjg.v16.i25.3196

关键词

Diffusion magnetic resonance imaging; Cholangiocarcinoma; Magnetic resonance imaging; Magnetic resonance cholangiopancreatography

向作者/读者索取更多资源

AIM: To determine the clinical value of diffusion-weighted imaging (DWI) for the diagnosis of extrahepatic cholangiocarcinoma (EHCC) by comparing the diagnostic sensitivity of DWI and magnetic resonance cholangiopancreatography (MRCP). METHODS: Magnetic resonance imaging examination was performed in 56 patients with suspected EHCC. T1-weighted imaging, T2-weighted imaging, MRCP and DWI sequence, DWI using single-shot spin-echo echo-planar imaging sequence with different b values (100, 300, 500, 800 and 1000 s/mm(2)), were performed. All cases were further confirmed by surgery or histopathological diagnosis. Two radiologists jointly performed the analysis of the DWI and MRCP images. Apparent diffusion coefficient (ADC) value and signal-noise ratio were calculated for EHCC. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value were tested using DWI with a b value of 500 s/mm(2) and MRCP images, respectively. RESULTS: Histopathological diagnosis confirmed that among the 56 cases, 35 were EHCC (20 hilar and 15 distal extrahepatic), 16 were cholangitis, and 5 were calculus of bile duct. Thirty-three out of the 35 EHCC cases were detected by DWI. EHCC exhibited differential levels of high signal intensity in DWI and low signal intensity in the ADC map. The mean value for ADC was (1.31 +/- 0.29) x 10(-3) mm(2)/s. The detection rate of EHCC was significantly higher by DWI (94.3%) than by MRCP (74.3%) (P < 0.05). There was a significant difference in sensitivity (94.3% vs 74.3%), specificity (100% vs 71.4%), accuracy (96.4% vs 73.2%), positive predictive value (100% vs 81.3%), and negative predictive value (91.3% vs 62.5%) between DWI and MRCP in diagnosing EHCC. CONCLUSION: DWI has a high sensitivity for the detection of EHCC as it shows the EHCC lesion more unambiguously than MRCP does. DWI can also provide additional clinically important information in EHCC patients when added to routine bile duct MR imaging protocols. (C) 2010 Baishideng. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据