4.8 Article

Dynamics of biocide emissions from buildings in a suburban stormwater catchment-Concentrations, mass loads and emission processes

期刊

WATER RESEARCH
卷 56, 期 -, 页码 66-76

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2014.02.033

关键词

Biocides; Terbutryn; Carbendazim; Facade coatings; Separated sewer

资金

  1. Miljostyrelsen (Danish EPA) [667-00065, 667-00066]
  2. AUFF grant

向作者/读者索取更多资源

Biocides such as isothiazolinones, carbamates, triazines, phenylureas, azoles and others are used to protect the surfaces of buildings, e.g. painted or unpainted render or wood. These biocides can be mobilized from the materials if rainwater gets into contact with these buildings. Hence, these biocides will be found in rainwater runoff (stormwater) from buildings that is traditionally managed as clean water in stormwater sewer systems and often directly discharged into surface waters without further treatment. By means of a 9 month event-based high resolution sampling campaign the biocide emissions in a small suburban stormwater catchment were analysed and the emission dynamics throughout the single rain events were investigated. Five out of twelve of the rain events (peak events) proved significantly higher concentrations than the rest (average) for at least one compound. Highest median concentrations of 0.045 and 0.052 mu g L-1 were found for terbutryn and carbendazim, while the concentrations for isoproturon, diuron, N-octylisothiazolinone, benzoisothiazolinone, cybutryn, propiconazole, tebuconazole, and mecoprop were one order of magnitude lower. However, during the peak events the concentrations reached up to 1.8 and 0.3 mu g L-1 for terbutryn and carbendazim, respectively. Emissions of an averaged single family house into the stormwater sewer turned out to be 59 and 50 mu g event(-1) house(-1) terbutryn and carbendazim, respectively. Emissions for the other biocides ranged from 0.1 to 11 mu g event-1 house-1. Mass load analysis revealed that peak events contributed in single events as much to the emissions as 11 average events. However, the mass loads were highly dependent on the amounts of rainwater, i.e. the hydraulic flow in the receiving sewer pipe. The analysis of the emission dynamics showed first flush emissions only for single parameters in three events out of twelve. Generally biocides seemed to be introduced into the stormwater system rather continuously during the respective events than in the beginning of them. Mass flows during the events did correlate to driving rain, whereas mass loads neither correlated to the length or the intensity of rainfall nor the length of dry period. (c) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据