期刊
WATER RESEARCH
卷 47, 期 4, 页码 1521-1528出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2012.11.002
关键词
Micropollutants; Ozonation; Photo-Fenton; Photocatalysis; Toxicity
资金
- Spanish Ministry of Science and Innovation [CTQ2009-13459-C05-01]
Conventional municipal wastewater treatment plants are not able to entirely degrade some organic pollutants that end up in the environment. Within this group of contaminants, Emerging Contaminants are mostly unregulated compounds that may be candidates for future regulation. In this work, different advanced technologies: solar heterogeneous photocatalysis with TiO2, solar photo-Fenton and ozonation, are studied as tertiary treatments for the remediation of micropollutants present in real municipal wastewater treatment plants effluents at pilot plant scale. Contaminants elimination was followed by Liquid Chromatography/Quadrupole ion trap Mass Spectrometry analysis after a pre-concentration 100:1 by automatic solid phase extraction. 66 target micropollutants were identified and quantified. 16 of those contaminants at initial concentrations over 1000 ng L-1, made up over 88% of the initial total effluent pollutant load. The order of micropollutants elimination efficiency under the experimental conditions evaluated was solar photo-Fenton > zonation > solar heterogeneous photocatalysis with TiO2. Toxicity analyses by Vibrio fischeri and respirometric tests showed no significant changes in the effluent toxicity after the three tertiary treatments application. Solar photo-Fenton and ozonation treatments were also compared from an economical point of view. (C) 2012 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐