4.8 Article

Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes

期刊

WATER RESEARCH
卷 42, 期 1-2, 页码 269-277

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.watres.2007.07.009

关键词

adenosine tri-phosphate (ATP); drinking water; flow cytometry; heterotrophic plate counts (HPCS); total cell concentration

向作者/读者索取更多资源

There are significantly more microbial cells in drinking water than what can be cultured on synthetic growth media. Nonetheless, cultivation-based heterotrophic plate counts (HPCs) are used worldwide as a general microbial quality parameter in drinking water treatment and distribution. Total bacterial cell concentrations are normally not considered during drinking water treatment as a design, operative or legislative parameters. This is mainly because easy and rapid methods for quantification of total bacterial cell concentrations have, up to now, not been available. As a consequence, the existing lack of data does not allow demonstrating the practical value of this parameter. In this study, we have used fluorescence staining of microbial cells with the nucleic acid stain SYBR(R) Green I together with quantitative flow cytometry (FCM) to analyse total cell concentrations in water samples from a drinking water pilot plant. The plant treats surface water (Lake Zilrich) through sequential ozonation, granular active carbon (GAC) filtration and membrane ultrafiltration (UF). The data were compared with adenosine tri-phosphate (ATP) measurements and conventional HPCs performed on the same water samples. We demonstrated that the impact of all three major treatment steps on the microbiology in the system could accurately be described with total cell counting: (1) ozonation caused chemical destruction of the bacterial cells; (2) GAC filtration facilitated significant regrowth of the microbial community; and (3) membrane UF physically removed the bacterial cells from the water. FCM typically detected 1-2 log units more than HPC, while ATP measurements were prone to interference from extracellular ATP released during the ozonation step in the treatment train. We have shown that total cell concentration measured with FCM is a rapid, easy, sensitive and importantly, a descriptive parameter of several widely applied drinking water treatment processes. (C) 2007 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据