4.4 Article

Functional electrical stimulation of the left recurrent laryngeal nerve using a vagus nerve stimulator in a normal horse

期刊

VETERINARY JOURNAL
卷 189, 期 3, 页码 346-348

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.tvjl.2010.07.008

关键词

Neuroprosthesis; Stimulation parameters; Cricoarytenoid dorsalis muscle; Recurrent laryngeal neuropathy

向作者/读者索取更多资源

The aim of this study was to assess the feasibility of implanting an existing vagus nerve stimulating (VNS) electrode around the recurrent laryngeal nerve. The stimulus response characteristics required to achieve abduction of the ipsilateral arytenoid by the VNS electrode in the normal horse could then be determined. The electrode was wound around the left recurrent laryngeal nerve at the cervical level and connected to a pulse generator. Stimulus response characteristics were obtained by measuring stimulated arytenoid displacement endoscopically in the standing, non-sedated horse. A full and sustained abduction of the arytenoid was obtained with a stimulation frequency of 25 Hz and intensity of 1 mA with a pulse width of 250 mu s. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据