Use of biosynthetic prosthesis (Omniflow II®) to replace infected infrainguinal prosthetic grafts - first results

期刊

VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE
卷 41, 期 3, 页码 215-220

出版社

VERLAG HANS HUBER HOGREFE AG
DOI: 10.1024/0301-1526/a000188

关键词

infected vascular graft; biosynthetic graft

资金

  1. Cook Inc.
  2. Medtronic Inc.
  3. W.L. Gore and Associates Inc.
  4. LeMAitre
  5. Datascope and Schwarz Pharma/Otsuka

向作者/读者索取更多资源

Background: The current treatment standard of infected infrainguinal prosthetic vascular grafts includes total graft explantation and autologous vascular reconstruction. In the absence of appropriate autologous venous graft material prosthetic grafts with increased bacterial resistance can be used, whereas reinfection rates are still higher than after autologous reconstruction. Biosynthetic grafts have shown low postoperative infection rates when used as elective bypass material. Their higher resistance to bacterial infection could make them an alternative to replace infected prosthetic grafts in the absence of autologous material. Patients and methods: Between November 2009 and April 2011, 7 patients with infected infrainguinal prosthetic grafts (Szilagyi 3; 3 supragenicular and 4 infragenicular reconstructions) presented to our institution. There were 4 early (< 3 months after implantation) and 3 late infections (> 3 months after implantation. All grafts were explanted and replaced by biosynthetic grafts (Omniflow II (R)), because the patient had no suitable peripheral vein for complete autologous replacement. In 2 cases a composite graft with greater saphenous vein was done. In 6 cases microbiological cultures from intraoperatively obtained species were positive. The initial broad spectrum antibiotic therapy was continued according to the antibiogram for 6 to 12 weeks. Results: There was no early or late reinfection during follow up (mean 9 months, range 4 - 20 months). During follow up we observed graft occlusions in 3 patients (1 due to kinking of the bypass, 1 due to progressive artheriosclerotic occlusion of the outflow vessels and 1 iatrogenic by external compression with a pressure cuff during arthroscopy). There were no early or late major amputations. One patient died with pneumonia 11 months postoperatively. Conclusions: In the absence of appropriate autologous material biosynthetic grafts seem to be a possible alternative to replace infected infrainguinal grafts. The different mechanical properties of biosynthetic grafts may be of certain disadvantage in infragenicular reconstructions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据