Objective To evaluate the accuracy of antenatal sonographic measurement of lower uterine segment (LUS) thickness in the prediction of risk of uterine rupture during a trial of labor (TOL) in women with a previous Cesarean section (CS). Methods PubMed and EMBASE were searched to identify articles published on the subject of sonographic LUS measurement and occurrence of a uterine defect after delivery. Four independent researchers performed identification of papers and data extraction. Selected studies were scored on methodological quality, and sensitivity and specificity of measurement of LUS thickness in the prediction of a uterine defect were calculated. We performed bivariate meta-analysis to estimate summary receiver operating characteristics (sROC) curves. Results We included 21 studies with a total of 2776 analyzed patients. The quality of included studies was good, although comparison was difficult because of heterogeneity. The estimated sROC curves showed that measurement of LUS thickness seems promising in the prediction of occurrence of uterine defects (dehiscence and rupture) in the uterine wall. The pooled sensitivity and specificity of myometrial LUS thickness for cut-offs between 0.6 and 2.0 mm was 0.76 (95% CI, 0.60-0.87) and 0.92 (95% CI, 0.82-0.97); cut-offs between 2.1 and 4.0 mm reached a sensitivity and specificity of 0.94 (95% CI, 0.81-0.98) and 0.64 (95% CI, 0.26-0.90). The pooled sensitivity and specificity of full LUS thickness for cut-offs between 2.0 and 3.0 mm was 0.61 (95% CI, 0.42-0.77) and 0.91 (95% CI, 0.80-0.96); cutoffs between 3.1 and 5.1 mm reached a sensitivity and specificity of 0.96 (95% CI, 0.89-0.98) and 0.63 (95% CI, 0.30-0.87). Conclusions This meta-analysis provides support or the use of antenatal LUS measurements in the prediction of a uterine defect during TOL. Clinical applicability should be assessed in prospective observational studies using a standardized method of measurement. Copyright (C) 2013 ISUOG. Published by John Wiley & Sons Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据