4.6 Article

Quantitative analysis of antral follicle number and size: a comparison of two-dimensional and automated three-dimensional ultrasound techniques

期刊

ULTRASOUND IN OBSTETRICS & GYNECOLOGY
卷 35, 期 3, 页码 354-360

出版社

WILEY
DOI: 10.1002/uog.7505

关键词

anti-Mullerian hormone; antral follicle count; antral follicle size; automated; ovarian reserve; reliability; SonoAVC (TM); three-dimensional ultrasound

向作者/读者索取更多资源

Objectives To compare two-dimensional (2D) ultrasound imaging with automated three-dimensional (3D) ultrasound imaging for the measurement of antral follicle number and size. Methods Twenty-four subjects aged <40 years underwent transvaginal ultrasound examination (Voluson E8) in the early follicular phase of the menstrual cycle. A 2D ultrasound scan of both ovaries was performed; each antral follicle was identified and then measured by taking the mean of two diameters. A 3D ultrasound dataset of both ovaries was then acquired and analyzed using Sonography-based Automated Volume Count (SonoAVC (TM)). The time taken to measure the size of all antral follicles in both ovaries was recorded in seconds for each technique. Antral follicle size was recorded to the nearest millimeter and counts for each 1-mm group were obtained. Antral follicle counts were also grouped according to five predefined size categories: 2.0-5.0 mm, 2.0-6.0 mm, 2.0-8.0 mm, 2.0-9.0 mm and 2.0-10.0 mm. Limits of agreement (LOA) and a paired t-test or Wilcoxon signed ranks test were used to analyze the data depending on their distribution. Results When antral follicle numbers were coin pared for each 1-mm follicle size group, 2D ultrasound imaging recorded more follicles measuring 3.0-3.99 mm (mean +/- SD, 4.11 +/- 3.70 vs. 2.63 +/- 2.31; P = 0.019) and 4.0-4.99 mm (mean SD, 4.63 +/- 4.86 vs. 2.68 +/- 2.89; P = 0.013) than did SonoAVC. LOA were widest with follicles measuring 3.0-3.99 mm (LOA, 6.38 and -3.43) and 4.0-4.99 mm (LOA, 7.99 and -4.09). The antral follicle count in each of the five predefined size categories was significantly lower with SonoAVC than with 2D ultrasound imaging (P <0.05). SonoAVC took significantly less time to measure the size and record the number of antral follicles than did 2D ultrasound imaging (mean SD, 132.05 +/- 56.23 s vs. 324.47 +/- 162.22 s; P < 0.001). Conclusions Fewer antral follicles are evident overall when SonoAVC is used to analyze 3D ultrasound data. The clinical significance of this remains to be determined but the automated technique is significantly quicker than is making measurements using 2D ultrasound imaging. Copyright (C) 2010 ISUOG. Published by John Wiley Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据