4.6 Article

Transvaginal ultrasound measurement of cervical length in the supine and upright positions versus Bishop score in predicting successful induction of labor at term

期刊

ULTRASOUND IN OBSTETRICS & GYNECOLOGY
卷 33, 期 2, 页码 213-220

出版社

WILEY
DOI: 10.1002/uog.6219

关键词

Bishop score; cervical length; funneling; labor induction; maternal postural change; ultrasound

向作者/读者索取更多资源

Objectives To examine the predictive value of cervical length as measured by transvaginal sonography (TVS) in supine and upright maternal positions for the mode of delivery and induction-to-delivery interval after induction of labor at term, and to compare these measurements with the Bishop score and its predictive value. Methods TVS for cervical length measurement in the supine and upright positions and digital examination of the cervix were performed in 68 nulliparous and 34 parous women before induction of labor at term. In assessing the predictive value of the Bishop score and TVS parameters for a vaginal delivery after labor induction only nulliparous women were included in the analysis, since all the parous women delivered vaginally. Both nulliparous and parous women were included in the analysis of the induction-to-delivery interval. The method of labor induction, oxytocin or prostaglandin, was determined on the basis of the pre-induction Bishop score. Results Logistic regression analysis showed in nulliparous women that only the cervical length measured in the upright position was a significant predictor of the need for Cesarean section (odds ratio 1.14; 95% CI, 1.02-1.27). The areas under the receiver-operating characteristics curve in predicting the need for Cesarean section because of failure to progress were higher for the cervical length, both in supine and upright positions, than for the Bishop score (0.66, 0.68 and 0.46, respectively). Only the Bishop score correlated significantly with the induction-to-delivery interval in both nulliparous and parous women. However, this may have been due to a selection bias, as no significant correlation with Bishop score was found when the oxytocin and prostaglandin induction-to-delivery intervals were analyzed separately. Conclusion Our results suggest that maternal postural change might improve the accuracy of sonographically-measured cervical length for predicting a vaginal delivery after induction of labor at term. However, our results need to be confirmed in a larger and more homogeneous population. Copyright (C) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据