Window-modulated compounding Nakagami imaging for ultrasound tissue characterization

期刊

ULTRASONICS
卷 54, 期 6, 页码 1448-1459

出版社

ELSEVIER
DOI: 10.1016/j.ultras.2014.04.024

关键词

Backscattered statistics; Compounding Nakagami imaging; Nakagami distribution; Nakagami imaging

资金

  1. National Science Council of the Republic of China (Taiwan) [NSC 102-2221-E-182-008]
  2. Chang Gung Memorial Hospital (Linkou, Taiwan) [CMRPD1C0711]
  3. Chang Gung Medical Research Program (CMRP) for Proton Therapy Basic Research [CMRPD1C0661, CMRPD1C0641]

向作者/读者索取更多资源

Ultrasound Nakagami parametric imaging is a useful tool for tissue characterization. Previous literature has suggested using a square with side lengths corresponding to 3 times the transducer pulse length as the minimum window for constructing the Nakagami image. This criterion does not produce sufficiently smooth images for the Nakagami image to characterize homogeneous tissues. To improve image smoothness, we proposed window-modulated compounding (WMC) Nakagami imaging based on summing and averaging the Nakagami images formed using sliding windows with varying window side lengths from 1 to N times the transducer pulse length in 1 pulse length step. Simulations (the number densities of scatterers: 2-16 scatterers/mm(2)) and experiments on fully developed speckle phantoms (the scatterer diameters: 20-106 mu m) were conducted to suggest an appropriate number of frames N and to evaluate the image smoothness and resolution by analyzing the full width at half maximum (FWHM) of the parameter distribution and the widths of the image autocorrelation function (ACF), respectively. In vivo ultrasound measurements on rat livers without and with cirrhosis were performed to validate the practical performance of the WMC Nakagami image in tissue characterization. The simulation results showed that using a range of N from 7 to 10 as the number of frames for image compounding reduces the estimation error to less than 5%. Based on this criterion, the Nakagami parameter obtained from the WMC Nakagami image increased from 0.45 to 0.95 after increasing the number densities of scatterers from 2 to 16 scatterers/mm(2). The FWHM of the parameter distribution (bins = 40) was 13.5 +/- 1.4 for the Nakagami image and 9.1 +/- 1.43 for the WMC Nakagami image, respectively (p-value < .05). The widths of the ACF for the Nakagami and WMC Nakagami images were 454 +/- 5.36 and 458 +/- 4.33, respectively (p-value > .05). In the phantom experiments, we also found that the FWHM of the parameter distribution for the WMC Nakagami image was smaller than that of the conventional Nakagami image (p-value < .05), and there was no significant difference of the ACF width between the Nakagami and WMC Nakagami images (p-value > .05). In the animal experiments, the Nakagami parameters obtained from the WMC Nakagami image for normal and cirrhotic rat livers were 0.62 +/- 0.08 and 0.92 +/- 0.07, respectively (p-value < .05). The results demonstrated that the WMC technique significantly improved the image smoothness of Nakagami imaging without resolution degradation, giving Nakagami model-based imaging the ability to visualize scatterer properties with enhanced image quality. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据