4.7 Review

First international comparative study of volatile fatty acids in aqueous samples by chromatographic techniques: Evaluating sources of error

期刊

TRAC-TRENDS IN ANALYTICAL CHEMISTRY
卷 51, 期 -, 页码 127-143

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.trac.2013.07.007

关键词

Analytical performance; Aqueous sample; Chromatography; Free fatty acid; Interlaboratory comparison; International comparative study; Monitoring; Proficiency-testing scheme; Source of error; Volatile fatty acid

向作者/读者索取更多资源

This first international proficiency-testing scheme evaluated the analytical performance and the state of practice in measurement of volatile fatty acids in aqueous samples. Gas chromatography and high-performance liquid chromatography were used by 25 laboratories from 15 different countries. Two reference materials were selected for analysis. The performance of each laboratory was assessed by the internationally-accepted z-score. The overall performance was rather poor. Among the causes of poor analytical performance, human errors and inadequate calibration were probably the major problems encountered. (C) 2013 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据