4.2 Article

Hemodynamic Contribution of Stem Cell Scaffolding in Acute Injured Myocardium

期刊

TISSUE ENGINEERING PART A
卷 18, 期 15-16, 页码 1652-1663

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/ten.tea.2011.0591

关键词

-

资金

  1. National Medical Research Council of Singapore
  2. SingHealth Foundation

向作者/读者索取更多资源

Tissue-engineered scaffolds may improve experimental outcomes in cardiac cell therapy by targeted delivery of stem cells and mechanically support an infarcted left ventricular (LV) wall. We transplanted cardiomyocyte-like cells (5 x 10(5)) with scaffolding via epicardial patching (cell patch, n = 17) or a low-dose intramyocardial hydrogel (LD hydrogel, n = 18), a high-dose (5 x 10(6)) intramyocardial hydrogel (HD hydrogel, n = 18) or transplanting a serum-free medium control (control, n = 13), a blank patch (n = 14), and a blank gel (n = 16) for targeted cardiomyoplasty in a myocardial infarcted rat model. LV real-time hemodynamics were assessed using a 1.9-F pressure-volume catheter 7 weeks after stem cell transplantation. All mode of scaffold transplantation protected diastolic function by preserving LV wall integrity that resulted in a lower end diastolic pressure-volume relationship (EDPVR) as compared to a control medium-injected group. Moreover, epicardial patching, but not hydrogel injection, reduced ventricular wall stress with a significantly better LV end diastolic pressure (EDP: 5.3 +/- 2.4mmHg vs. 9.6 +/- 6.9mmHg, p < 0.05) as compared to control. Furthermore, epicardial patching additionally preserved systolic function by modulating negative remodeling through restricting dilatation of the LV chamber. In comparison to control, an improved ejection fraction in the cell patch group (80.1%+/- 5.9% vs. 67.9%+/- 3.2%, p < 0.01) was corroborated by load-independent enhancement of the end systolic pressure-volume relationship (ESPVR: 0.88 +/- 0.61mmHg/uL vs. 0.29 +/- 0.19mmHg/uL, p < 0.05) and preload recruitable stroke work (PRSW: 68.7 +/- 26.4mmHg vs. 15.6 +/- 16.2mmHg, p < 0.05) in systolic function. Moreover, the cell patch group (14.2 +/- 1.7 cells/high-power field vs. 7.4 +/- 1.6 cells/high power field, p < 0.05) was significantly better in myocardial retention of transplanted stem cells as compared to the LD hydrogel group. Collectively, myocardial transplantation of compliant scaffolding materials alone may physically improve wall mechanics, largely independent of stem cells. However, epicardially grafted cell patch conferred added systolic contractility by improving stem cell retention and cellular alignment leading to improved LV remodeling and geometric preservation postinfarction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据