期刊
THIN-WALLED STRUCTURES
卷 73, 期 -, 页码 273-280出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2013.08.018
关键词
Concrete-filled steel tube; Axially loaded; Notch; Column strength; Load-displacement response
资金
- Key Subject Foundation of Henan Province [504906]
- Key Subject Foundation of HPU [509902]
- Doctor Foundation of Henan Polytechnic University [B2009-2]
Compressive tests of the CFT stub columns with artificial notches in the steel tubes were conducted in this paper to investigate the effects of the material imperfections of steel tubes on mechanical performances of the CFT stub columns. The load-displacement responses, column strength and confining effects were discussed in detail. A parametric study, including the notch length, notch orientation, concrete strength and steel ratio, was also conducted. The results indicated that the notched CFT specimens had quite different failure modes from the intact CFT specimens. A notched CFT specimen might fail by cracking of the steel tube or closing of the notch, which was determined by the notch orientation. The results also showed that the notched CFT specimens had lower mechanical performance than those intact CFT specimens because the notch steel tube could not offer sufficient confining effect on the concrete core inside it. Based on the experimental results, an empirical equation for predicting the column strength of a notched CFT column was proposed. (C) 2013 Elsevier Ltd. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据