4.7 Article

Buckling capacities of axially loaded, cold-formed, built-up C-channels

期刊

THIN-WALLED STRUCTURES
卷 47, 期 2, 页码 190-201

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.tws.2008.05.014

关键词

Built-up sections; Cold-formed compression members; Modified effective length; Column shear

向作者/读者索取更多资源

Cold-formed, built-up members are common compression elements in cold-formed steel joists, and these built-up members are susceptible to unique buckling behaviors. Built-up member design is addressed in Section C4.5 of the American Iron and Steel Institute 2001 Specification. Over 150 experimental compression tests on closed-section, built-up members formed of intermediately welded c-channels were conducted, and these experimental values were compared to theoretical buckling capacities based on the Section C4.5 modified slenderness ratio. Use of the modified slenderness ratio was exceedingly conservative. Capacities based on the unmodified slenderness ratio and C4.5 fastener and spacing provisions were consistently conservative. Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据