A Rapid HPLC-ESI-MS/MS Method for Determination of Dihydrouracil/Uracil Ratio in Plasma: Evaluation of Toxicity to 5-Flurouracil in Patients With Gastrointestinal Cancer

期刊

THERAPEUTIC DRUG MONITORING
卷 34, 期 1, 页码 59-66

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/FTD.0b013e318240405f

关键词

uracil; dihydrouracil; HPLC-ESI-MS/MS; 5-fluorouracil toxicity; DPD

资金

  1. Coordenacao de Aperfeicxoamento de Pessoal de Nivel Superior (CAPES)
  2. Fundacxao de Amparo a Pesquisa do Estado de Minas Gerais (FAPEMIG)

向作者/读者索取更多资源

Background: A liquid chromatography-tandem mass spectrometry method for the simultaneous quantitation of endogenous uracil (U) and dihydrouracil (UH2) was developed and tested in a Brazilian population of patients with gastrointestinal cancer previously exposed to 5-fluorouracil (5FU). Methods: The analytes were extracted by a liquid-liquid method using 5-clorouracil as internal standard. The separation was performed on a reversed-phase XTerra C-18 column with a mobile phase composed of methanol and aqueous 0.1% ammonium hydroxide (15: 85). Mass spectrometry detection was carried out using negative electrospray ionization and selected reaction monitoring. Bovine serum albumin was employed as an alternative matrix to prepare the calibration standards, aiming to avoid the measurement of physiologic U and UH2. Calibration curves were constructed over the range of 5-200 ng/mL for U and 10-500 ng/mL for UH2. Results: The mean RSD values in the intrarun precision were 6.5% and 10.0% and in the interrun precision were 7.8% and 9.0% for U and UH2, respectively. The mean accuracy values were within the range of 90%-110% for both analytes. The analytes were stable in plasma under different conditions of temperature and time. The validated method was successfully applied to determine the plasma concentrations of U and UH2 in patients with gastrointestinal cancer (n = 32) previously treated with 5FU and for whom clinical toxicity was well documented. U concentrations varied from 21.8 to 56.6 ng/mL, whereas UH2 concentrations varied from 57.7 to 271.5 ng/mL. UH2/U ratio ranged from 1.56 to 6.18. Conclusions: The method has proved to provide a quick, reliable, and reproducible quantitation of the plasma concentrations of U and its metabolite UH2. The UH2/U ratios did not discriminate patients previously exposed to 5FU with and without severe toxicities, possibly due to the small sample. Further studies in a larger population are desirable.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据