4.7 Article

Biocompatible phosphonic acid-functionalized silica nanoparticles for sensitive detection of hypoxanthine in real samples

期刊

TALANTA
卷 117, 期 -, 页码 536-542

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2013.08.061

关键词

Silica; Phosphonic acid-functionalized; Biomimetic; Xanthine oxidase; Biosensor

资金

  1. NSFC [20971069]
  2. NSFJS [8E2011196]
  3. foundation of the Jiangsu education committee [CXZZ11_0890]
  4. Key Scientific and Technological Project of Shanghai Science and Technology Commission [10391901800]
  5. Priority Academic Program Development of Jiangsu Higher Education Institution, Base of PER of PJRP of Jiangsu [BY2011109]
  6. Foundation of Jiangsu Collaborative Innovation Center of Biomedical Functional Materials
  7. Natural Science Foundation of the Jiangsu Higher Education Institutions of China [11KJB150009]

向作者/读者索取更多资源

A novel hypoxanthine biosensor fabricated by immobilizing the xanthine oxidase (XOD) onto the phosphonic acid-functionalized silica (SiO2-P) film on the surface of glassy carbon electrode (GCE) was designed and constructed in this work. A biomimetic platform was designed with the phosphonic acid-functionalized silica nanoparticles (SiO2-P NPs) synthesized by the method of reverse microemulsion and electrostatic binding. In such a platform, XOD was selected as model protein to fabricate hypoxanthine biosensor based on SiO2-P NPs. The nanocomposite was characterized with transmission electron microscopy (TEM), energy dispersive X-ray spectrometer (EDS) and electrochemical impedance spectroscopy (EIS). Based on the advantageous functions of SiO2-P NPs, the entrapped XOD could preserve its bioactivity and exhibited an excellent electrochemical behavior with a formal potential of -0.37 V in phosphate buffer solution (PBS, pH = 7). Response studies to hypoxanthine were carried out using current-time response curve. The biosensor exhibited a wide linear response ranging from 1.00 x 10(-6) to 2.61 x 10(-4) M. The detection limit of 2.33 x 10(-7) M at a signal-to-noise ratio of 3 was lower than that most reported previously. In addition, the electrode modified with XOD/(SiO2-P NPs) film also had a strong anti-interference ability in the presence of uric acid (UA) and ascorbic acid (AA). The assay results of hypoxanthine in fish samples were in a good agreement with the reference values. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据