4.7 Article

Systematic comparisons of various spectrophotometric and colorimetric methods to measure concentrations of protein, peptide and amino acid: Detectable limits, linear dynamic ranges, interferences, practicality and unit costs

期刊

TALANTA
卷 98, 期 -, 页码 123-129

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2012.06.058

关键词

BCA; Biuret; Bradford; Lowry; Ninhydrin; Protein assay

资金

  1. Office of the Higher Education Commission and Mahidol University under the National Research Universities Initiative
  2. Thailand Research Fund [RTA5380005]
  3. Chalermphrakiat Grant, Faculty of Medicine Siriraj Hospital

向作者/读者索取更多资源

There is limited and inconclusive information regarding detectable limits and linear dynamic ranges of various quantitative protein assays. We thus performed systematic comparisons of seven commonly used methods, including direct spectrophotometric quantitation at lambda 205 and lambda 280 nm (A205 and A280, respectively), bicinchoninic acid (BCA), Biuret, Bradford, Lowry and Ninhydrin methods. Purified BSA, porcine kidney extract, tryptic digested peptides derived from purified BSA, and glycine, were used as representative purified protein, complex protein mixture, peptide and amino acid, respectively. Bradford method was the most sensitive assay (LOD=0.006 mg/ml) and had the widest range of detectability (LOD-UOD=0.006-100 mg/ml) for purified protein and complex protein mixture. For peptide, A205, A280, Lowry and Ninhydrin methods had a comparable LOD (0.006 mg/ml), but Ninhydrin method had the widest detectability range (LOD-UOD=0.006-100 mg/ml). For amino acid, A205 and Ninhydrin methods had a comparable LOD (0.006 mg/ml), but A205 had a wider detectability range (LOD-UOD=0.006-6.250 mg/ml). Biuret method offered the widest linear dynamic range for purified protein and complex protein mixture (0.391-100 mg/ml), A280 offered the widest linear dynamic range for peptide (0.024-6.250 mg/ml), and Ninhydrin method offered the widest linear dynamic range for amino acid (0.024-0.195 mg/ml). Both Laemmli's and 2-D lysis buffers had dramatic interfering effects on all assays. Concerning the practicality and unit costs, A205 and A280 were the most favorable. Among the colorimetric methods, Bradford method consumed the least amount of samples and shortest analytical time with the lowest unit cost. These are the most extensive comparative data of commonly used quantitative protein assays that will be useful for selecting the most suitable method for each study. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据