4.7 Article

Application of chemometrics and FTIR for determination of viscosity index and base number of motor oils

期刊

TALANTA
卷 81, 期 3, 页码 1096-1101

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2010.02.003

关键词

Motor oil; Base number; Viscosity index; Multivariate calibration; ASTM; FTIR

资金

  1. Royal Scientific Society (RSS)

向作者/读者索取更多资源

The viscosity index (VI) and the base number (BN) of motor oils are the most important parameters to be measured in order to assess their performance and service time. Both parameters were simply obtained for virgin and recycled motor oil samples using multivariate calibration based on the FTIR data. Analysis showed that the PLS-1 has outperformed CLS and PCR for the oil parameters prediction. Five and four PLS-1 latent variables were found optimum to obtained the VI and the BN from the FTIR data: respectively. With high accuracy (99-102%) and precision (3-11%), the BN could be determined over the range 4.57-16.45 mg KOH g(-1) and the VI over the range 96-153. The outputs of the PLS-1 were found comparable to those obtained by the expensive and time-consuming ASTM methods. This developed method is highly recommended for quick monitoring of the motor oil quality parameters. (c) 2010 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据