Determination of toxic elements in plastics from waste electrical and electronic equipment by slurry sampling electrothermal atomic absorption spectrometry

期刊

TALANTA
卷 81, 期 4-5, 页码 1781-1787

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2010.03.038

关键词

Slurry analysis; ETAAS; Plastic solid waste

资金

  1. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP, SP, Brazil) [05/60566-1]
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

向作者/读者索取更多资源

Cadmium, chromium, lead and antimony were determined in slurries prepared using pulverized samples of personal computers and mobile phones dispersed in dimethylformamide medium. Determinations were carried out by electrothermal atomic absorption spectrometry (ETAAS) using a graphite furnace atomic absorption spectrometer The optimization of the experimental conditions (chemical modifier. pyrolysis time, pyrolysis temperature and atomization temperatures) was accomplished by evaluating pyrolysis and atomization curves. Optimization was also used to determine the temperatures corresponding to the best sensitivities and the lowest background signals The pyrolysis temperatures were Fixed at 600 degrees C (for Cd), 700 degrees C (for Pb), 1100 degrees C (for Sb), and 1200 degrees C (for Cr), atomization temperatures were established as 1400 degrees C (for Cd), 1300 degrees C (for PI)), 1900 degrees C (for Sb). and 2300 degrees C (for Cr), and the chemical modifier (50 mu g NH4H2PO4 + 3 mu g Mg(NO3)(2) was used for Cd and Pb while 5 mu g Pd + 3 mu g Mg(NO3)(2) was used for Sb) The use of a chemical modifier for Cr determination was not necessary. The characteristic masses were 1 9 pg for Cd, 32.3 pg for Pb, 54.1 pg for Sb, and 9.1 pg for Cr, Calibration was performed using standard additions in a range of 5-20 mu g L-1 for Cd, 5-30 mu g L-1 for Cr, 12 5-50 mu g L-1 for Pb, and 25-100 mu g L-1 for Sb with linear correlation coefficients higher than 0.99 Limits of detection were 0 9, 1.4, 6.8, and 2.9 mu g L-1 for Cd. Pb, Sb, and Cr. respectively. The results indicate that recoveries for all metals agreed at a 95% confidence level when a paired t-test was applied and presented good precision The accuracy of the proposed method was evaluated by addition-recovery experiments, showing results in the 96-112% range, and also by comparison of the results using Student's t-test with another method developed using ETAAS for digested samples Analyte concentrations in the samples investigated varied from 5 to 525, 51 to 611, and 30 to 458 mg kg(-1) for Cd, Cr, and Pb. respectively, while the content of SI) was in the 02-1 65% range. (C) 2010 Elsevier B V All rights reserved

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据