4.7 Article

Comparative evaluation of Dy(III) selective poly(vinyl) chloride based membrane electrodes of macrocyclic tetraimine Schiff's bases

期刊

TALANTA
卷 79, 期 2, 页码 528-533

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2009.04.019

关键词

Dy(III); PVC; Ion-selective electrode; Schiff's bases

资金

  1. Ministry of Human Resource Development (MHRD), New Delhi, India

向作者/读者索取更多资源

Three different derivatives of macrocyclic tetraimine Schiff's base have been synthesized and explored as a neutral ionophores for preparing poly(vinyl chloride) based membrane sensors selective to Dy3+. The addition of sodium tetraphenyl borate and various plasticizers, viz., o-NPOE, DBP, DBBP, DOP and CN has been found to substantially improve the performance of the sensors. The best performance was obtained with the sensor no. I having membrane of Schiff's base (SL-1) with composition (w/w) SL-1 (4.5%): PVC (30.5%): o-NPOE (59.5%): NaTPB (5.5%). This sensor exhibits Nernstian response with slope 19.4 mV/decade of activity in the concentration range of 10(-8) to 1.0 x 10(-2) M Dy3+, performs satisfactorily over wide pH range of (2.8-7.2) with a fast response time (10 s). The sensor was also found to work satisfactorily in partially non-aqueous media up to 20% (v/v) content of acetonitrile, methanol or ethanol. The proposed sensor can be used over a period of 1.5 months without significant drift in potentials. The sensor has been also utilized for the determination of Dy3+ level in different soil samples (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据