4.5 Article

A highly sensitive non-enzymatic ascorbate sensor based on copper nanoparticles bound to multi walled carbon nanotubes and polyaniline composite

期刊

SYNTHETIC METALS
卷 161, 期 21-22, 页码 2427-2433

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.synthmet.2011.09.020

关键词

Non enzymatic; Ascorbic acid; Multiwalled carbon nanotubes; Polyaniline; Copper nanoparticies; Amperometric biosensor

向作者/读者索取更多资源

A novel, stable and highly sensitive non-enzymatic ascorbic acid sensor was developed using copper nanoparticles (CuNPs), carboxylated multi-walled carbon nanotubes (MWCNTs) and polyaniline (PANI) composite electrodeposited on gold electrode. The modified Au electrode was characterized using scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), cyclic voltammetry and impedance spectroscopy. The linear sweep voltammetry peak current showed a linear dependence on the ascorbic acid concentration and a linear calibration curve was obtained in the range, 5-600 mu M of ascorbic acid with a correlation coefficient (r) of 0.998. The sensors response time was less than 2s and detection limit was 1.0 mu M (at signal/noise = 3). When tested with serum, fruits and vegetables, the sensor exhibited high electrocatalytic activity, fast response and good selectivity against common interfering species, suggesting its potential to be developed as a non-enzymatic ascorbic acid sensor. Crown Copyright (C) 2011 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据