4.4 Article

Dry sliding wear behaviour of plasma transferred arc hardfaced colmonoy surface

期刊

SURFACE ENGINEERING
卷 25, 期 6, 页码 440-448

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1179/174329408X281812

关键词

Dry sliding wear; Plasma transferred arc hardfacing; Carbon steel; Colmonoy; Analysis of variance; Design of experiments

资金

  1. Board of Research in Nuclear Sciences (BRNS)
  2. Department of Atomic Energy (DAE), Govt. of India, Mumbai [2003/20/36/1-BRNS]

向作者/读者索取更多资源

Dry sliding wear occurs when two bodies are in sliding contact. During the process of sliding, fragments may be pulled out from one surface and they may stick on to the other. Later on, these may get transferred back or may become loose wear particles. This paper reports the effects of different experimental conditions on the dry sliding wear behaviour of nickel based alloy (Colmonoy) surface produced by plasma transferred arc (PTA) hardfacing process. The wear test was conducted in a pin on roller wear testing machine, under constant sliding distance of 1 km. Mathematical models were developed to estimate wear rate incorporating rotational speed, applied load and roller hardness using statistical tools such as design of experiments, regression analysis and analysis of variance. It is found that the wear resistance of the PTA hardfaced nickel based alloy (Colmonoy) surface is five times better than that of the substrate (carbon steel).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据