4.7 Article

Antibacterial properties of vacuum plasma sprayed titanium coatings after chemical treatment

期刊

SURFACE & COATINGS TECHNOLOGY
卷 204, 期 5, 页码 685-690

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.surfcoat.2009.09.010

关键词

Titanium coating; Antibacterial; Silver; Vacuum plasma spraying; Chemical treatment

向作者/读者索取更多资源

Implant-related infection is one of the common clinical complications that cause high rates of mortality and morbidity in orthopedic surgery. Endowing implant antibacterial properties is a useful method to reduce such infection. In this paper, vacuum plasma sprayed titanium coatings were treated by NaOH solution firstly, and then antimicrobial silver was introduced into the coatings by immersing in 0.02 mM (denoted as CA1), 0.06 mM (denoted as CA2) and 0.1 mM (denoted as CA3) Ag+ containing calcification solution. Antibacterial property of the treated titanium coatings was examined by employing three types of bacteria stains, Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus. X-Ray diffraction and scanning electron microscopy were used to observe the phase composition and surface morphology of the modified titanium coatings. Results showed that all of the three kinds of coatings exhibited more than 90.00% antibacterial ratio except CA1 to Staphylococcus aureus which is 63.30%. The release of silver in physiological environment was monitored and it was found that the excellent antibacterial property of the treated coatings was attributed to the release of silver. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据