4.7 Review

Diagnostic accuracy of magnetic resonance angiography for internal carotid artery disease -: A systematic review and meta-analysis

期刊

STROKE
卷 39, 期 8, 页码 2237-2248

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1161/STROKEAHA.107.509877

关键词

carotid arteries; carotid artery stenosis; magnetic resonance angiography; angiography; contrast-enhanced magnetic resonance angiography

资金

  1. Intramural NIH HHS Funding Source: Medline

向作者/读者索取更多资源

Background and Purpose - Accurate diagnosis of the degree of internal carotid artery (ICA) stenosis is needed for decisions regarding optimal stroke prevention. Noninvasive magnetic resonance angiography (MRA) is being proposed and used as a replacement for the gold standard, intra-arterial angiography. Our purpose was to perform a systematic review and diagnostic meta-analysis to determine the sensitivity and specificity of time-of-flight (TOF) MRA and contrast-enhanced (CE) MRA for the detection of (1) high-grade (>= 70% to 99%) ICA stenoses; ( 2) ICA occlusions; ( 3) moderately severe (50% to 69%) ICA stenoses; and ( 4) compare the overall accuracy of the 2 MRA techniques. Methods - The medical literature on MRA and the diagnosis of ICA steno-occlusive disease was reviewed through the PubMed, EMBASE, and SCOPUS databases. All publication years were included through to November 2006. Studies were eligible for inclusion if they compared the accuracy of TOF or CE MRA for the detection of ICA disease against intra-arterial angiography and reported sufficient data. Results - The overall sensitivity of TOF MRA for the detection of >= 70% to 99% ICA stenoses was 91.2% (95% CI: 88.9% to 93.1%) with a specificity of 88.3% (86.7% to 89.7%), whereas the sensitivity of CE MRA was 94.6% (92.4% to 96.4%) with a specificity of 91.9% (90.3% to 93.4%). For the detection of ICA occlusions, the sensitivity of TOF MRA was 94.5% ( 91.2% to 96.8%) and the specificity was 99.3% (98.9% to 99.6%), whereas the sensitivity and specificity values for CE MRA were 99.4% (96.8% to 100%) and 99.6% (99.2% to 99.9%), respectively. For moderately severe ( 0% to 69%) stenoses, TOF MRA had a sensitivity of only 37.9% (29.3% to 47.1%) and a specificity of 92.1% (89.6% to 94.1%); for CE MRA, the pooled sensitivity value was somewhat better at 65.9% (57.0% to 74.0%), whereas the specificity was 93.5% (91.3% to 95.3%). Conclusions - TOF MRA and CE MRA showed high accuracy for the detection of high- grade ICA stenoses and occlusions with CE MRA having the edge over TOF MRA, but had only poor (TOF MRA) to fair (CE MRA) sensitivity for the detection of moderately severe stenoses.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据