4.2 Article

Quantitative Error Assessment in Pattern Matching: Effects of Intensity Pattern Noise, Interpolation, Strain and Image Contrast on Motion Measurements

期刊

STRAIN
卷 45, 期 2, 页码 160-178

出版社

WILEY
DOI: 10.1111/j.1475-1305.2008.00592.x

关键词

digital image correlation; matching; error assessment; expectation and variance for image motion; intensity interpolation; intensity pattern noise; probabilistic formulation

资金

  1. Sandia National Laboratory [551836]
  2. NASA [NNX07AB46A]
  3. Department of Mechanical Engineering at the University of South Carolina
  4. [W911NF-06-1-0216]

向作者/读者索取更多资源

Basic concepts in probability are employed to develop analytic formulae for both the expectation (bias) and variance for image motions obtained during subset-based pattern matching. Specifically, the expectation and variance in image motions in the presence of uncorrelated Gaussian intensity noise for each pixel location are obtained by optimising a least squares intensity matching metric. Results for both 1D and 2D image analyses clearly quantify both the bias and the covariance matrix for image motion estimates as a function of: (a) interpolation method, (b) sub-pixel motion, (c) intensity noise, (d) contrast, (e) level of uniaxial normal strain and (f) subset size. For 1D translations, excellent agreement is demonstrated between simulations, theoretical predictions and experimental measurements. The level of agreement confirms that the analytical formulae can be used to provide a priori estimates for the 'quality' of local, subset-based measurements achievable with a given pattern. For 1D strain with linear interpolation, theoretical predictions are provided for the expectation and co-variance matrix for the local displacement and strain parameters. For 2D translations with bi-linear interpolation, theoretical predictions are provided for both the expectation and the co-variance matrix for both displacement components. Theoretical results in both cases show that the expectations for the local parameters are biased and a function of: (a) the interpolation difference between the translated and reference images, (b) magnitude of white noise, (c) decimal part of the motion and (d) intensity pattern gradients. For 1D strain, the biases and the covariance matrix for both parameters are directly affected by the strain parameter p(1) as the deformed image is stretched by (1 + p(1)). For 2D rigid body motion case, the covariance matrix for measured motions is shown to have coupling between the motions, demonstrating that the directions of maximum and minimum variability do not generally coincide with the x and y directions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据