4.5 Article

Validation of a Noninvasive Technique to Precisely Measure In Vivo Three-Dimensional Cervical Spine Movement

期刊

SPINE
卷 36, 期 6, 页码 E393-E400

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0b013e31820b7e2f

关键词

accuracy; image registration; kinematics; RSA; x-ray

资金

  1. NIH/NIAMS [R03AR056265]

向作者/读者索取更多资源

Study Design. In vivo validation during functional loading. Objective. To determine the accuracy and repeatability of a model-based tracking technique that combines subject-specific computed tomographic (CT) models and high-speed biplane x-ray images to measure three-dimensional (3D) in vivo cervical spine motion. Summary of Background Data. Accurate 3D spine motion is difficult to obtain in vivo during physiological loading because of the inability to directly attach measurement equipment to individual vertebrae. Previous measurement systems were limited by two-dimensional (2D) results and/or their need for manual identification of anatomical landmarks, precipitating unreliable and inaccurate results. All previous techniques lack the ability to capture true 3D motion during dynamic functional loading. Methods. Three subjects had 1.0-mm-diameter tantalum beads implanted into their fused and adjacent vertebrae during anterior cervical discectomy and fusion surgery. High-resolution CT scans were obtained after surgery and used to create subject-specific 3D models of each cervical vertebra. Biplane x-ray images were collected at 30 frames per second while the subjects performed flexion/extension and axial rotation movements 6 months after surgery. Individual bone motion, intervertebral kinematics, and arthrokinematics derived from dynamic radiostereophotogrammetric analysis served as a gold standard to evaluate the accuracy of the model-based tracking technique. Results. Individual bones were tracked with an average precision of 0.19 and 0.33 mm in nonfused and fused bones, respectively. Precision in measuring 3D joint kinematics in fused and adjacent segments averaged 0.4 mm for translations and 1.1 degrees for rotations, while anterior and posterior disc height above and below the fusion were measured with a precision ranging between 0.2 and 0.4 mm. The variability in 3D joint kinematics associated with tracking the same trial repeatedly was 0.02 mm in translation and 0.06 degrees in rotation. Conclusion. The 3D cervical spine motion can be precisely measured in vivo with submillimeter accuracy during functional loading without the need for bead implantation. Fusion instrumentation did not diminish the accuracy of kinematic and arthrokinematic results. The semiautomated model-based tracking technique has excellent repeatability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据