Diagnostic Imaging of Spinal Deformities Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager

期刊

SPINE
卷 35, 期 9, 页码 989-994

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/BRS.0b013e3181bdcaa4

关键词

spine radiographs; scoliosis; radiation dose; image quality

资金

  1. CHU Sainte-Justine's ethic committee approval
  2. Canadian Foundation for Innovation
  3. Biospace Med

向作者/读者索取更多资源

Study Design. Clinical trial comparing image quality and entrance dose between Biospace EOS system, a new slot-scanning radiographic device, and a Fuji FCR 7501S computed radiography (CR) system for 50 patients followed for spinal deformities. Objective. Based on their physical properties, slot-scanners show the potential to produce image quality comparable to CR systems using less radiation. This article validates this assertion by comparing a new slot-scanner to a CR system through a wide-ranging evaluation of dose and image quality for scoliosis examinations. Summary of Background Data. For each patient included in this study, lateral and posteroanterior images were acquired with both systems. For each system, entrance dose was measured for different anatomic locations. Methods. Dose and image quality being directly related, comparable images were obtained using the same radiograph tube voltage on both systems while tube currents were selected to match signal-to-noise ratios on a phantom. Different techniques were defined with respect to patient's thickness about the iliac crests. Given dose amplitudes expected for scoliosis examinations, optically stimulated luminescence dosimeters were chosen as optimal sensors. Two radiologists and 2 orthopedists evaluated the images in a randomized order using a questionnaire targeting anatomic landmarks. Visibility of the structures was rated on a 4 level scale. Image quality assessment was analyzed using a Wilcoxon signed-rank tests. Results. Average skin dose was reduced from 6 to 9 times in the thoracoabdominal region when using the slot-scanner instead of CR. Moreover, image quality was significantly better with EOS for all structures in the frontal view (P < 0.006) and lateral view (P < 0.04), except for lumbar spinous processes, better seen on the CR (P < 0.003). Conclusion. We established that the EOS system offers overall enhanced image quality while reducing drastically the entrance dose for the patient.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据