4.3 Article

On the feasibility of using motor imagery EEG-based brain-computer interface in chronic tetraplegics for assistive robotic arm control: a clinical test and long-term post-trial follow-up

期刊

SPINAL CORD
卷 50, 期 8, 页码 599-608

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/sc.2012.14

关键词

spinal cord injury; brain computer/machine interface; electroencephalogram; mechatronic/robotic arm device; quality of life

资金

  1. European Commission [MEXT-CT-2004-014194]
  2. Teaching Emergency Hospital 'Bagdasar-Arseni' (TEHBA), Bucharest, Romania University

向作者/读者索取更多资源

Study design: Survey and long-term clinical post-trial follow-up (interviews/correspondence) on nine chronic, post spinal cord injury (SCI) tetraplegics. Objective: To assess feasibility of the use of Electroencephalography-based Brain-Computer Interface (EEG-BCI) for reaching/grasping assistance in tetraplegics, through a robotic arm. Settings: Physical and (neuromuscular) Rehabilitation Medicine, Cardiology, Neurosurgery Clinic Divisions of TEHBA and UMPCD, in collaboration with 'Brain2Robot' (composed of the European Commission-funded Marie Curie Excellence Team by the same name, hosted by Fraunhofer Institute-FIRST), in the second part of 2008. Methods: Enrolled patients underwent EEG-BCI preliminary training and robot control sessions. Statistics entailed multiple linear regressions and cluster analysis. A follow-up-custom questionnaire based-including patients' perception of their EEG-BCI control capacity was continued up to 14 months after initial experiments. Results: EEG-BCI performance/calibration-phase classification accuracy averaged 81.0%; feedback training sessions averaged 70.5% accuracy for 7 subjects who completed at least one feedback training session; 7 (77.7%) of 9 subjects reported having felt control of the cursor; and 3 (33.3%) subjects felt that they were also controlling the robot through their movement imagination. No significant side effects occurred. BCI performance was positively correlated with beta (13-30 Hz) EEG spectral power density (coefficient 0.432, standardized coefficient 0.745, P-value=0.025); another possible influence was sensory AIS score (range: 0 min to 224 max, coefficient -0.177, standardized coefficient -0.512, P=0.089). Conclusion: Limited but real potential for self-assistance in chronic tetraplegics by EEG-BCI-actuated mechatronic devices was found, which was mainly related to spectral density in the beta range positively (increasing therewith) and to AIS sensory score negatively. Spinal Cord (2012) 50, 599-608; doi:10.1038/sc.2012.14; published online 13 March 2012

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据