4.6 Article

Optimization and life-cycle cost of health clinic PV system for a rural area in southern Iraq using HOMER software

期刊

SOLAR ENERGY
卷 84, 期 4, 页码 710-714

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2010.01.024

关键词

Photovoltaics (PV); Stand-alone system; Rural electrification; Rural area in Iraq; System; Design

资金

  1. U.S. Department of Energy [DE-AC36-08-G028308]

向作者/读者索取更多资源

This paper addresses the need for electricity of rural areas in southern Iraq and proposes a photovoltaic (PV) solar system to power a health clinic in that region. The total daily health clinic load is 31.6 kWh and detailed loads are listed. The National Renewable Energy Laboratory (NREL) optimization computer model for distributed power, HOMER, is used to estimate the system size and its life-cycle cost. The analysis shows that the optimal system's initial cost, net present cost, and electricity cost is US$ 50,700, US$ 60,375, and US$ 0.238/kW h, respectively. These values for the PV system are compared with those of a generator alone used to supply the load. We found that the initial cost, net present cost of the generator system, and electricity cost are US$ 4500, US$ 352,303, and US$ 1.332/kW h, respectively. We conclude that using the PV system is justified on humanitarian, technical, and economic grounds. (C) 2010 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据