4.7 Article

Isotope (14C and 13C) analysis of deep peat CO2 using a passive sampling technique

期刊

SOIL BIOLOGY & BIOCHEMISTRY
卷 41, 期 12, 页码 2477-2483

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.soilbio.2009.09.004

关键词

Peat; CO2; Radiocarbon; Molecular sieve

资金

  1. NERC
  2. NERC [NRCF010001] Funding Source: UKRI
  3. Natural Environment Research Council [NRCF010001] Funding Source: researchfish

向作者/读者索取更多资源

We developed and tested a new method to collect CO2 from the surface to deep layers of a peatland for radiocarbon analysis. The method comprises two components: i) a probe equipped with a hydrophobic filter that allows entry of peat gases by diffusion, whilst simultaneously excluding water and ii) a cartridge containing zeolite molecular sieve that traps CO2 passively. We field tested the method by sampling at depths of between 0.25 and 4 m at duplicate sites within a temperate raised peat bog. CO2 was trapped at a depth-dependent rate of between similar to 0.2 and 0.8 ml d(-1), enabling sufficient CO2 for routine C-14 analysis to be collected when left in place for several weeks. The age of peatland CO2 increased with depth from modern to similar to 170 BP for samples collected from 0.25 m, to 4000 BP at 4 m. The CO2 was younger, but followed a similar trend to the age profile of bulk peat previously reported for the site (Langdon and Barber, 2005). delta C-13 values of recovered CO2 increased with depth. CO2 collected from the deepest sampling probes was considerably C-13-enriched (up to similar to+97 parts per thousand) and agreed well with results reported for other peatlands where this phenomenon has been attributed to fermentation processes. CO2 collected from plant-free static chambers at the surface of the mire was slightly C-14-enriched compared to the contemporary atmosphere, suggesting that surface CO2 emissions were predominantly derived from carbon fixed during the post-bomb era. However, consistent trends of enriched C-13 and depleted C-14 in chamber CO2 between autumn and winter samples were most likely explained by an increased contribution of deep peat CO2 to the surface efflux in winter. The passive sampling technique is readily portable, easy to install and operate, causes minimal site disturbance, and can be reliably used to collect peatland CO2 from a wide range of depths. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据